The amplitude response to vapours of all odorants tested in the maxillary palp is significantly reduced. The antennal response is unaffected. Maxillary palps have no gross anatomical defects and the electrical conduction properties are normal.
very small (<3mV) ERG, even with high intensity stimuli
Pak.